$20.5
$25
VSWR 1.0, the cable temperature 20 ºC, environment temperature 40 ºC, the inner conductor temperature 100 ºC Marking requirements:HENGXIN TECHNOLOGY HCAFBY(Z)-50-5 XXXXXXXX(series NO.) 0000m Capacity Per Spool:500m;Spool Packing:φ480*φ150*310mm
| Construction | |||||
| Product Type | HCAFBY-50-5-6(PLMR300) | HCAFBYZ-50-5-6(PLMR300) | |||
| Product Code | 2.3.21.01 | 2.3.22.11 | |||
| Jacket Colour | BLACK | ||||
| Inner Conductor Material | CCA( Copper Clad Aluminum) | ||||
| Dielectric Material | Physical Foam Polyethylene PE | ||||
| Outer Conductor Material | Bonded aluminum/polyester/aluminum tape+TC Wire Braiding | ||||
| Outer Conductor Coverage | 80% | ||||
| Jacket Material | PE | LSZH | |||
| Dimensions | |||||
| Inner Conductor | 1.80±0.02 mm | ||||
| Dielectric | 4.80±0.10 mm | ||||
| Shields | 5.60±0.20 mm | ||||
| Jacket | 7.60±0.20 mm | ||||
| Electrical Property | |||||
| Capacitance | 80pF/m | ||||
| Impedance | 50±2 Ω | ||||
| Velocity | 82.0% | ||||
| Insulation Resistance | >5000 MΩ.km | ||||
| Cut-off Frequency | 22.8 GHz | ||||
| Withstanding Voltage(AC) | 2.0 KV | ||||
| Sparkover Voltage | 3.0 KV | ||||
| Peak Power Rating | 9.23 KW | ||||
| Screen Efficiency | ≥85 dB | ||||
| VSWR | |||||
| 800~1000MHz | ≤1.15 | ||||
| 1700~2000MHz | ≤1.20 | ||||
| 2000~2400MHz | ≤1.25 | ||||
| Attenuation | |||||
| Frequency(MHz) | Attenuation(dB/100 m) | Frequency(MHz) | Attenuation(dB/100 m) | ||
| 100 | 6.3 | 1500 | 26.8 | ||
| 150 | 7.8 | 1800 | 29.7 | ||
| 280 | 10.8 | 1900 | 30.6 | ||
| 350 | 12.1 | 2000 | 31.5 | ||
| 400 | 13.0 | 2200 | 33.3 | ||
| 800 | 18.9 | 2500 | 35.8 | ||
| 900 | 20.2 | 2800 | 38.3 | ||
| 1200 | 23.7 | 3000 | 39.9 | ||
| *Maximum attenuation value shall be 110% of the nominal attenuation value. | |||||
| Environmental and Mechanical Property | |||||
| Operating Temperature Range | -40ºC~+85ºC | ||||
| Minmum Bending Radius | 75 mm | ||||
| Minmum Bending Temperature | -15ºC | ||||
| Standard Conditions: | |||||
| VSWR 1.0, the cable temperature 20 ºC, environment temperature 40 ºC, the inner conductor temperature 100 ºC | |||||
| Marking requirements:HENGXIN TECHNOLOGY HCAFBY(Z)-50-5 XXXXXXXX(series NO.) 0000m | |||||
| Capacity Per Spool:500m;Spool Packing:φ480*φ150*310mm | |||||